Testing Objectives:
Verify if the product can withstand external vibrations
Test criteria:
Refer to GB/T 2423.10,IEC 68-2-6,GB/T 9410,YD/T 1059
Parameter:
Equipment Name: Sinusoidal vibration test plateform
Platform size: 500mm*500mm
Mode of vibration : Electromagnetic Suction
Vibration Direction : triaxial test
Loading capacity: 50Kg
Amplitude: 0--8mm
Vibration Frequency: 1--600Hz
Objectives
Verify product intermodulation characteristics
Criteria:
Refer GB/T 9410,YD/T 1059
Parameter:
Equipment Name: intermodulation testing
Size: 3500mm×3500mm×3500mm
Output Power: 0-20W
FREQUENCY RANGE: 400MHz--6000MHz
Temperature : 15℃~35℃
"Barometric pressure:86kPa~106kPa"
Relative Humidity : 45%~75%
Test objectives:
Verify if the product meets the requirements for high and low temperature and alternating hot and humid environments
Test basis:
Refer To GB/T 2423.1,GB/T 2423.2,IEC 68-2-1,IEC 68-2-2,GB/T 9410,YD/T 1059
Parameter of Testing Equpment:
Equipment Name: Programmable Temperature & Humidity Chamber
Nominal Volume: 500L
Temperature Range: -70℃ → +100℃
Temperature Fluctuation: ±0.5℃
Humidity Range: 20% → 98%RH
Test Objectives:
Verify whether the product meets the requirements of salt spray corrosion
Testing criteria:
GB/T 2423.17,IEC 68-2-52,GB/T 9410,YD/T 1059
Parameter of Equipment:
Equipment Name: Salt Spray test chamber
Nominal Volume: 2400L
Spray Volume: 1~2ml/80cm²/h
Spray pressure: 1.00±0.01kgf/cm2
Density: 5±1% NaC1
Temperature: 35±2℃